WebSep 12, 2014 · "Joe Lstiburek recommends that flash-and-batt jobs include a minimum of 1 inch of closed-cell spray foam in Zone 5. If you're in Zone 4, there is no minimum foam thickness, because condensation problems are unlikely in Zone 4. That said, it's hard to spray an even 1/2-inch layer of spray foam. WebOct 6, 2011 · If you use flash and batt, and also use a warm-side vapor barrier, you would have the dreadful “Double vapor barrier.” With that, any vapor that gets past the interior barrier might condense and be trapped in the wall by the outer barrier. ... The designer and builder of the 2024 Fine Homebuilding House detail why they chose mineral-wool ...
Flash and Batt Insulation Strategy - YouTube
Flash and batt is a hybrid insulation approach combining fiberglass insulation and closed-cell spray foam. Fiberglass devoured the insulation industry in the 1970s, for obvious reasons. It is cheap, simple to install (if not easy to install well), and readily available. Any weekend warrior with a stapler and utility knife can … See more Flash and batt insulation is a method of insulating standard stud walls by augmenting fiberglass batts with 2 inches of closed-cell spray foam applied to the interior of the building sheathing. The standard framing … See more R-Value:While it isn’t a radical improvement over standard walls, flash and batt systems do have a higher R-value. Replacing 2 inches of fiberglass (at around R-3.5 per … See more Thermal bridging:One of the big knocks on flash and batt is that it doesn’t address thermal bridging. The spray foam provides a little more R-value than fiberglass, but the heat flowing through the uninsulated wood studs still … See more WebAug 23, 2024 · A: Combining spray foam with fiber insulation in an unvented cathedral ceiling (or wall) is often referred to as “flash and batt.” This is a pretty easy way to boost your R-value and get an airtight air barrier without … bin bag fashion ideas
Flash and batt - GreenBuildingAdvisor
WebFeb 12, 2024 · We are building a house in Ohio, zone 5. 2×4 construction. Builder is recommending flash and batt insulation with 1/2″ of closed cell spray foam, R-13 batt, and 6 mil poly between the fiberglass and sheetrock. From what I have read on here that seems like a fairly risky way to insulate the house. WebJan 11, 2024 · Insulation is flash & batt over the roof and walls as shown in the attachment (with the exception that I think instead of the batts with listed R-value like I asked for, I got 6″ batts on the roof and 3″ in the walls. ... WebMar 23, 2024 · 153K views 4 years ago In this Video Matt shows off a Hybrid Insulation system for a High Performance Home utilizing the Flash & Batt method. This home has … cyrus beams